HVAC/Heating and Air Conditioning Powell, OH

Why should you choose the best HVAC company in Powell, OH?

Your family's comfort is our #1 priority. A dependable heating and cooling system is a must to keep your home comfortable for you and your loved ones.

Experienced HVAC professionals

Westin Air’s teams of HVAC professionals are highly trained and are here to install a new system for you or maintain and service your present system.

Fair and Transparent Pricing

We offer fair and transparent pricing with no hidden add-ons! Westin Air avoids gimmicks in our pricing because we all know there is nothing absolutely free! We try to give you the best quality installation and service, while charging a fair and competitive price.

Emergency Service Available 24/7

If your heating equipment stops working in the winter season or your cooling system stops working in the middle of the summer, give us a call! We offer emergency service calls 24/7.

Request Service

HVAC Coupons in Powell, Ohio.

$35 OFF

Seasonal Inspection

1 coupon per customer.
Not valid with any other coupon or discount.
Expires 8/31/25

$35 OFF

HVAC Repair services

Excludes Diagnostic fee

1 coupon per customer.
Not valid with any other coupon or discount.
Expires 8/31/25

$200 OFF

Any New AC, Heat Pump, or Furnace

1 coupon per customer.
Not valid with any other coupon or discount.
Expires 8/31/25

Frequently asked questions about Westin Air in Powell, Ohio

Do you offer emergency repair services?

Westin Air does offer emergency HVAC repair services in Powell, Ohio.

Do you offer free estimates for replacement and installation?

Absolutely! We offer free estimates to replace your heating and cooling units or add a new unit to your home.

Do you offer a free 2nd opinion?

Our service department offers a free second opinion on cracked heat exchangers or condenser coil leaks. Give us a call at 614-794-1259 to schedule.

Do you offer air quality solutions?

Yes, we have a variety of products to improve your indoor air quality. Visit our indoor air quality page to see what options we offer, including our highly recommended iWave.

Do you offer maintenance services on systems installed by other companies?

Yes, Westin Air Heating and Cooling offers maintenance services on equipment installed by other companies.

Westin Air Heating and Cooling Services in Powell, OH

Furnace Repair in Powell, Ohio

When your furnace stops working properly, you need to have a heating and cooling company that you can count on. Westin Air has been providing furnace repairs to the residents of Powell for many years. Our highly-trained technicians will give you a flat rate cost to repair your furnace with no added surprises. Because Westin Air keeps their service trucks well-stocked with parts that are the most commonly used, we can often perform the repair immediately.

 

Powell homeowners that need our furnace repair services can call us at 614-794-1259, 24 hours a day to get scheduled for their diagnostic visit. One of our friendly, knowledgeable repair technicians will find and explain the problem, and will provide you with the cost of the repair.

Furnace Maintenance in Powell, Ohio

Powell homeowners should not wait for frigid winter temperatures to take a toll on their furnace, before they think about calling Westin Air for furnace maintenance appointment. Regular maintenance on your furnace extends the life of your furnace, along with keeping it running efficiently. No one wants to have their furnace breakdown when it is very cold outside, so consider calling Westin Air for an appointment for your furnace maintenance.

 

To help avoid unexpected problems with your furnace, we encourage you to sign up for an annual maintenance plan. You can check out the different plans we offer by clicking here:

Download Our Maintenance Plan

 

During a furnace tune-up or maintenance visit, our Westin Air service technician will inspect and test your furnace for safety issues that might be present, and for any problems that could result in a furnace breakdown, or that might impact the efficiency of your furnace. Problems that are found early, are much easier to repair and usually less costly, than a problem that has brought your furnace operation to a halt. Also, a well-maintained furnace tends to use less energy to keep your home warm.

 

Furnace Replacement in Powell, Ohio

Powell is a lovely small town with lots of great offerings for its residents. The beautiful homes in the area that Powell residents enjoy, deserve to have furnaces with all the features to provide comfortable, energy-efficient operation. If you are considering replacing your old furnace, give Westin Air a call at 614-794-1259 to schedule a free, no obligation appointment with one of our trained comfort consultants. At this appointment, they will collect all the necessary information pertaining to your current furnace, answer your questions, and ask you about your expectations of a new system. Sometimes, the capacity of the current furnace might be questionable. If you or our comfort consultant think that the size of your current furnace might not be optimal for your home, they will do a Manual J load calculation to accurately determine the correct capacity needed to keep you home comfortable, even in the coldest weather. The load calculation is provided at no cost to the homeowner.

 

Westin Air offers what we feel are some of the finest brands of heating and cooling equipment on the market. We sell furnaces manufactured by Trane, Tempstar, and Daikin. Because we limit the brands, our installation crews are very knowledgeable about each one, and have the knowledge to properly install every furnace that we sell. Should the need for a furnace replacement arise unexpectedly, we've got you covered! We offer several payment options and financing plans. If you are interested in obtaining financing, talk to our comfort consultant and visit our financing page by clicking here:

Request a Quote

 

Heat Pump Repair in Powell, Ohio

If you have an all-electric home and rely on a heat pump for your main source of heat, you don't want it breaking down unexpectedly. If that does happen, just call Westin Air at 614-794-1259, and make an appointment for one of our highly trained service technicians to stop by your home to diagnose the problem, and provide you with a flat-rate repair cost. .Our service technicians keep their trucks well-stocked with the most commonly used parts, and can often do the repair on the spot.

 

Give us a call 24/7 if your heat pump breaks down, or just seems like it is not working properly.

Heat Pump Maintenance in Powell, Ohio

Because heat pumps work all year long, providing heat in the winter and cooling in the summer, you will want to keep your unit properly maintained. To avoid surprise break downs, we highly recommend having regular maintenance performed on the unit. At the maintenance appointment. Westin Air's service technicians will check your heat pump and the air handler. They will inform you of anything out of the ordinary that needs to be corrected, along with a flat rate cost of doing the repair. We do have several maintenance plans that you might want to consider, in order to keep your heat pump running in top-notch condition.

Heat Pump Replacement in Powell, Ohio

If your system is up in years, or just seems to not be able to keep up in the heating and cooling of your home, you might want to consider replacing your old heat pump. Call our office to set up an appointment for one of our Comfort Consultants to come to your home and give you a proposal for a new heat pump. We offer many great options, along with some that qualify for the Federal tax credit. Westin Air has great options to consider.

Air Conditioner Repair in Powell, Ohio

If the unexpected happens, and your AC breaks down in the middle of the hot, humid summer, give us a call. A Westin Air Heating and Cooling technician will be able to quickly diagnose the problem and get your AC up and running again.

 

If you notice any of the above, call Westin Air and we will send one of our service technicians to diagnose the problem, and get the problem fixed quickly.

Air Conditioner Maintenance in Powell, Ohio

In the midwest, summers are often quite hot and humid. To avoid an unexpected air conditioner breakdown, be sure your air conditioner has been inspected and is ready to keep your home cool all summer long. Give Westin Air a call and schedule an AC maintenance appointment.. Preventative maintenance is very important in order to have a dependable, energy efficient air conditioner. We offer one time maintenance calls, or you can sign up for one of our annual maintenance plans.

 

A Westin Air technician will test and check out your unit, along with performing some routine maintenance tasks, so that your air conditioner will be something you can count on to keep you cool! If the technician should find any problem, he will discuss his findings with you, and give recommendations for correcting the problem.

Air Conditioner Replacement in Powell, Ohio

Powell homeowners will need to replace their air conditioners at some point in time, even though they have kept them properly maintained. An AC can be expected to run a good 10-15 years before needing replaced. Good maintenance practices tend to prolong the life of an AC, but sooner or later, it will be time to replace your unit. Some people choose to wait until their AC is in need of a costly repair to replace, while other people choose to proactively replace their AC, in order to avoid having a major breakdown and no cooling in the middle of the summer heat. Whichever way you think about it, when the time comes, you will want a qualified, reputable local company to install your new air conditioner. Westin Air has been taking care of Powell homeowners for many years and will be happy to install a new air conditioner for you, when the time comes.

 

About Powell, Ohio

Founded by Judge Thomas Powell, Powell lays in between the Scioto and Olentangy Rivers. It has been ranked 18th on Money Magazines 100 of the Best Places to Live in the United States and we want to make sure the residents of 43065 are taken care of and treated well. Westin Air prides itself in the exceptional customer service we provide. From the moment your call is answered, we treat you like we would treat our own mother. Westin Air is our family and we invite you to become part of that family.

 

Recent Jobs and Reviews in Powell, OH

Rated 4.9 out of 5 stars based on 17 customer reviews

Job Locations and Reviews

Graham M.
Graham M. Checked in
Perform cooling maintenance on 2 systems. Coils clean Test run cooling on each system Run capacitors within spec Delta T NE- 19° SW- 21° Units are in proper operation at this time.
Powell, OH 43065
Condenser coil 75% damaged due to what appears to be a power washer 
System running very high head pressure as a result
Capacitor tested OK
Cause for outdoor fan motor stopping is likely due to overheating from the damaged coil and the unit getting too hot
System has a history of refrigerant leaks, service record on the ductwork from 2014 shows 1lb of r22 and leak sealant added
Exhaust and intake are incorrectly pitched
Condenser coil 75% damaged due to what appears to be a power washer 
System running very high head pressure as a result
Capacitor tested OK
Cause for outdoor fan motor stopping is likely due to overheating from the damaged coil and the unit getting too hot
System has a history of refrigerant leaks, service record on the ductwork from 2014 shows 1lb of r22 and leak sealant added
Exhaust and intake are incorrectly pitched
Nate G.
Nate G. Checked in
Condenser coil 75% damaged due to what appears to be a power washer System running very high head pressure as a result Capacitor tested OK Cause for outdoor fan motor stopping is likely due to overheating from the damaged coil and the unit getting too hot System has a history of refrigerant leaks, service record on the ductwork from 2014 shows 1lb of r22 and leak sealant added Exhaust and intake are incorrectly pitched
Powell, OH 43065
seth p.
seth p. Checked in
Install Honeywell vision pro 8000, set up for two stage geothermal, programmable with automatic changeover, connect to home Wi-Fi and confirm operation. Homeowner is responsible for creating a Honeywell account and connecting to the system *** Due to unforeseen circumstances and age of the equipment the single pump cannot be replaced. During an attempt today the pump motor assembly came apart in pieces with the impeller seized in the housing of the flow center with a broken drive shaft. *** Recommend replacing the pressurized water furnace flow center with a two pump non-pressurized replacement NP2 fc2glnp or equivalent
Powell, OH 43065
Powell, OH - 2019 Trane high efficiency AC running in great condition. Electronic air filter cleaning. Tested operation. System is working and pulling correct power. Suspect that blub for green light has burned out. No corrective action needed. Indoor delta t of 19F with supply temp of 52F. Refrigerant pressures are within spec. High 275psi with 11F SC, low 115psi with 10F SH. Water flushed outdoor coils to remove dirt and debris. Outdoor fan motor and compressor are operating within specs. 40/5uf capacitor is new as of 8-17. System is operating properly, efficiently and ready for Summer.
Brandon P.
Brandon P. Checked in
2019 Trane high efficiency AC running in great condition. Electronic air filter cleaning. Tested operation. System is working and pulling correct power. Suspect that blub for green light has burned out. No corrective action needed. Indoor delta t of 19F with supply temp of 52F. Refrigerant pressures are within spec. High 275psi with 11F SC, low 115psi with 10F SH. Water flushed outdoor coils to remove dirt and debris. Outdoor fan motor and compressor are operating within specs. 40/5uf capacitor is new as of 8-17. System is operating properly, efficiently and ready for Summer.
Powell, OH 43065
Graham M.
Graham M. Checked in
Upon arrival inspected mini split heads and found 0° delta T inspected outdoor suction at 16psi while running. 115 ambient. Unit low on refrigerant. Perform leak search on all components and found leak on outdoor lineset. Have to cut out the line and repair. Quote approved for repair. Will return and zoomlock leaking lineset.
Powell, OH 43065
seth p.
seth p. Checked in
Upon arrival the power was turned off at the 70 amp breaker supplying the geothermal 2009 water furnace premier envision will not stop running when the thermostat turns off AND it will not engage y2 for high stage coolant Confirm system will shut down when thermostat Powers disabled Grounded pressure is at 0 PSI Free pressurized ground loops to 40 PSI with house water pressure Inspect replacement evaporator coil and run test system for proper refrigerant pressures Discovered the TXV sensing bulb was not attached and dangling free in the compressor compartment. Reattached TXV sensing bulb in the original location Suspect refrigerant circuit has possible contaminants causing fluctuations in the refrigerant pressures that will not stabilize Test run 2 pump flow center Minor oil drips we're also discovered on the discharge copper line. Refrigerant pressures are within specs or no additional testing is required at this time Homeowner will purchase and install his own two stage heat p
Powell, OH 43065
Brandon P.
Brandon P. Checked in
Found geothermal unit for second floor locked out on compressor failure to start code, checked capacitor and incoming voltage. Both are good. Reset code and perform test run from thermostat. System came on as it should. During rest run, check all electrical parameters to make sure that was no issues. Suspect that when power was lost to the house, and then came back on, the furnace control was glitched and went into a lockout code. No issues found or suspected with unit at this time.
Powell, OH 43065
Nate G.
Nate G. Checked in
Signed up for gold maintenance Diagnosed failed capacitor Condenser fan motor wouldn't start Cooled motor with water System operating normally at this time Condenser coil in desperate need of a thorough cleaning. Need to return for maintenance ASAP
Powell, OH 43065
Inspection of furnace showed that blower was operating properly. 20x25 pre-filter was very clogged preventing airflow. Low airflow caused indoor coil and lineset to freeze up. 20x25x4 main air filter in decent condition.  Tested refrigerant pressures. Pressures are spot on with a 18F SH. System is operating in cooling at this time. Keith would like a full system replacement quote to be prepared.
Inspection of furnace showed that blower was operating properly. 20x25 pre-filter was very clogged preventing airflow. Low airflow caused indoor coil and lineset to freeze up. 20x25x4 main air filter in decent condition.  Tested refrigerant pressures. Pressures are spot on with a 18F SH. System is operating in cooling at this time. Keith would like a full system replacement quote to be prepared.
Brandon P.
Brandon P. Checked in
Inspection of furnace showed that blower was operating properly. 20x25 pre-filter was very clogged preventing airflow. Low airflow caused indoor coil and lineset to freeze up. 20x25x4 main air filter in decent condition. Tested refrigerant pressures. Pressures are spot on with a 18F SH. System is operating in cooling at this time. Keith would like a full system replacement quote to be prepared.
Powell, OH 43065
Powell, OH - Upon arrival found unit with overflow pan full with water. Shop vac all water out and test run unit. Unit started cooling and everything looked good outside 300 psi 9° subcool 109psi 16° superheat. Upon further inspection found air coil inside was putting out 39° at the suction line and after the upwards U bend it reached 51°. Oil is likely slugging in coil suction line causing freeze up. Have to return, recover refrigerant, modify lineset to remove the suction line lift, and then recharge and test run system.
Graham M.
Graham M. Checked in
Upon arrival found unit with overflow pan full with water. Shop vac all water out and test run unit. Unit started cooling and everything looked good outside 300 psi 9° subcool 109psi 16° superheat. Upon further inspection found air coil inside was putting out 39° at the suction line and after the upwards U bend it reached 51°. Oil is likely slugging in coil suction line causing freeze up. Have to return, recover refrigerant, modify lineset to remove the suction line lift, and then recharge and test run system.
Powell, OH 43065
Graham M.
Graham M. Checked in
Cooling preventative maintenance performed Check filter - 16x25x4 due soon 2/25 - landlord will replace Check coil for any buildup debris in drain pan and flush with water Set up thermometers Rinse down outdoor coil with garden hose Check capacitor MFD - 40+5 @ 40.4+5.03 Verify pressures and HP-SC/LP-SH 330psi 120psi 10° superheat Delta T - 19° The Air handler and AC are in optimal running conditions.
Powell, OH 43065
Done
Done
Jeramie T.
Jeramie T. Checked in
Done
Powell, OH 43065
Nate G.
Nate G. Checked in
Changed air filters on furnace Found capacitor failed on outdoor unit Also found compressor wire burnt up Repaired burnt wire and installed a new terminal Replaced capacitor System operating normally at this time
Powell, OH 43065
seth p.
seth p. Checked in
Service warranty Upon arrival the system was completely shut down with no blower or geothermal operation for the second floor split system located in the Attic. Thermostat is calling for cooling but reading 86 indoor temp. Attic equipment inspection discovered a tripped off water safety switch in the air coil overflow pan. No water is currently present but has most likely evaporated due to 115° in the attic space. Repositioned safety switch 3/8 inch off the bottom of the pan and out from underneath the line set Recently installed line set insulation is separating from the double-sided tape. (Possible condensation points). Resecured all line set replacement armaflex Cooling system run test from thermostat confirms 20° cooling delta t from 90ra to 70sa Homeowner is resetting temperature on thermostat to 78
Powell, OH 43065
Graham M.
Graham M. Checked in
Replace bad 40+5 capacitor test run air conditioner and verify refrigerant pressures were adequate. 11° superheat 66° filter new today told homeowner to start washing air conditioner
Powell, OH 43065
Install new Trane air conditioner
Equipment:
Air Conditioner- Trane 
Model #: 4TTR3042N1000AA
Serial #: 234344183F
Coil- Trane Uncased A-Coil
Model #: 4PXACU42BS3 
Serial #: 21233HKT5G

Installation:
*Reuse existing thermostat
*Reconnect to existing high voltage electric
*Transition to existing supply ductwork
*Start up and commission new system

Warranty:
This Trane air conditioner is New Old Stock from 2024. The manufacturers parts warranty on it expires 1/28/2029. This air conditioner has never been used and is new in the original factory packaging. 
2 Year Westin Air labor warranty (Annual maintenance must be performed)
Install new Trane air conditioner
Equipment:
Air Conditioner- Trane 
Model #: 4TTR3042N1000AA
Serial #: 234344183F
Coil- Trane Uncased A-Coil
Model #: 4PXACU42BS3 
Serial #: 21233HKT5G

Installation:
*Reuse existing thermostat
*Reconnect to existing high voltage electric
*Transition to existing supply ductwork
*Start up and commission new system

Warranty:
This Trane air conditioner is New Old Stock from 2024. The manufacturers parts warranty on it expires 1/28/2029. This air conditioner has never been used and is new in the original factory packaging. 
2 Year Westin Air labor warranty (Annual maintenance must be performed)
Jason D.
Jason D. Checked in
Install new Trane air conditioner Equipment: Air Conditioner- Trane Model #: 4TTR3042N1000AA Serial #: 234344183F Coil- Trane Uncased A-Coil Model #: 4PXACU42BS3 Serial #: 21233HKT5G Installation: *Reuse existing thermostat *Reconnect to existing high voltage electric *Transition to existing supply ductwork *Start up and commission new system Warranty: This Trane air conditioner is New Old Stock from 2024. The manufacturers parts warranty on it expires 1/28/2029. This air conditioner has never been used and is new in the original factory packaging. 2 Year Westin Air labor warranty (Annual maintenance must be performed)
Powell, OH 43065
Turned system on for testing. Let run for approximately 15 minutes to test refrigerant and simulate normal operation procedure. Refrigerant pressures are slightly overcharged, not anything to worry about. Compressor is pulling ~12A while operating. This measurement is withing specifications but on the high end. When shut down, compressor stops instantly. Both the high Amp draw, and instant stopping can indicate a higher than normal amount of friction on the internal of the compressor. Due to the age of the unit, in case of a compressor failure, full system replacement is highly recommended. System is operating at this time but a timeline for operation or breakdown cannot be given. AC model and serial numbers are hard to read. Done over with black sharpie and wiped off to make them legible. Model and serial number put into a note on file.
Turned system on for testing. Let run for approximately 15 minutes to test refrigerant and simulate normal operation procedure. Refrigerant pressures are slightly overcharged, not anything to worry about. Compressor is pulling ~12A while operating. This measurement is withing specifications but on the high end. When shut down, compressor stops instantly. Both the high Amp draw, and instant stopping can indicate a higher than normal amount of friction on the internal of the compressor. Due to the age of the unit, in case of a compressor failure, full system replacement is highly recommended. System is operating at this time but a timeline for operation or breakdown cannot be given. AC model and serial numbers are hard to read. Done over with black sharpie and wiped off to make them legible. Model and serial number put into a note on file.
Brandon P.
Brandon P. Checked in
Turned system on for testing. Let run for approximately 15 minutes to test refrigerant and simulate normal operation procedure. Refrigerant pressures are slightly overcharged, not anything to worry about. Compressor is pulling ~12A while operating. This measurement is withing specifications but on the high end. When shut down, compressor stops instantly. Both the high Amp draw, and instant stopping can indicate a higher than normal amount of friction on the internal of the compressor. Due to the age of the unit, in case of a compressor failure, full system replacement is highly recommended. System is operating at this time but a timeline for operation or breakdown cannot be given. AC model and serial numbers are hard to read. Done over with black sharpie and wiped off to make them legible. Model and serial number put into a note on file.
Powell, OH 43065
Checkout refrigerant pressures, Amp draw, and cleanliness of outdoor units. Screenshit data of refrigerant and Amp draw to send to Daikin. Indoor units are operating within spec. West furnace is pulling 7.4A on fan motor, East unit is pulling 6.7A. Both are within spec and the difference is most likely due to ductwork setup.  I don't think that blower electrical usage would be counted in the estimated energy usage report as the Daikin system does not monitor that. Photos of electrical and refrigeration systems uploaded to file for future reference. No issues found, nor suspected during today's visit. Only notable thing is that the west side thermostat is in a location where it can get a decent amount of sunlight coming through and warming up that area which can cause longer run times. Daikin can be contacted regarding the energy usage report. Wes or Renee may need to be the ones to contact Daikin as the systems and usage reports are under their name.
Checkout refrigerant pressures, Amp draw, and cleanliness of outdoor units. Screenshit data of refrigerant and Amp draw to send to Daikin. Indoor units are operating within spec. West furnace is pulling 7.4A on fan motor, East unit is pulling 6.7A. Both are within spec and the difference is most likely due to ductwork setup.  I don't think that blower electrical usage would be counted in the estimated energy usage report as the Daikin system does not monitor that. Photos of electrical and refrigeration systems uploaded to file for future reference. No issues found, nor suspected during today's visit. Only notable thing is that the west side thermostat is in a location where it can get a decent amount of sunlight coming through and warming up that area which can cause longer run times. Daikin can be contacted regarding the energy usage report. Wes or Renee may need to be the ones to contact Daikin as the systems and usage reports are under their name.
Brandon P.
Brandon P. Checked in
Checkout refrigerant pressures, Amp draw, and cleanliness of outdoor units. Screenshit data of refrigerant and Amp draw to send to Daikin. Indoor units are operating within spec. West furnace is pulling 7.4A on fan motor, East unit is pulling 6.7A. Both are within spec and the difference is most likely due to ductwork setup. I don't think that blower electrical usage would be counted in the estimated energy usage report as the Daikin system does not monitor that. Photos of electrical and refrigeration systems uploaded to file for future reference. No issues found, nor suspected during today's visit. Only notable thing is that the west side thermostat is in a location where it can get a decent amount of sunlight coming through and warming up that area which can cause longer run times. Daikin can be contacted regarding the energy usage report. Wes or Renee may need to be the ones to contact Daikin as the systems and usage reports are under their name.
Powell, OH 43065
seth p.
seth p. Checked in
Install geothermal loop pipe insulation Insulate all in the house ground loop water lines between the wall foundation and both basement installed split system geothermal units Computer scan both systems, no diagnostics alerts or lockouts since last in-house service Per Tamara, Jackson Geothermal injected leak stop in the groundwater solution Today's running water pressure test is 40 PSI
Powell, OH 43065
seth p.
seth p. Checked in
Attic system Replace both liquid line and suction line split system service King valves Recover all refrigerant Evacuate system Replace both valves Nitrogen pressure test full system for leaks 427psi hold Triple evac with 1 nitrogen purge to 700 microns Recharge to factory specs with previously recovered refrigerant (110 oz R410a) Replace condensate drain trap on attic air coil 3/4cpvc Reseal coil doors and line set insulation in attic Cooling system maintenance on both upstairs and downstairs equipment Both systems are running in very good condition at this time Air filters are on schedule with homeowner Repressurize ground loops from 15 to 50 psi Downstairs system had 18 high pressure service code logged but no hard lockouts or active codes at this time. Suspect heating season condition or low water pressure in the ground loop for cooling season
Powell, OH 43065
Powell, OH - 2021 Tempstar AC running in great condition. 20x25x4 air filter in good condition. Visual inspection of indoor coil. Flush drain pan and drain lines. Run test unit in cooling mode from thermostat. Delta t of 20F with supply temp of 52F. Refrigerant pressures are within spec. High 275psi with 11F SC, low 120psi with 14F SH. Water flushed outdoor coils to remove dirt and debris. 70/7.5 capacitor reading within spec. Outdoor fan motor and compressor are operating within specs. System is operating properly, efficiently and ready for Summer.
Brandon P.
Brandon P. Checked in
2021 Tempstar AC running in great condition. 20x25x4 air filter in good condition. Visual inspection of indoor coil. Flush drain pan and drain lines. Run test unit in cooling mode from thermostat. Delta t of 20F with supply temp of 52F. Refrigerant pressures are within spec. High 275psi with 11F SC, low 120psi with 14F SH. Water flushed outdoor coils to remove dirt and debris. 70/7.5 capacitor reading within spec. Outdoor fan motor and compressor are operating within specs. System is operating properly, efficiently and ready for Summer.
Powell, OH 43065
seth p.
seth p. Checked in
Install two replacement high voltage fuses for the hot water generator and flow center 10a glass buss (Waterfurnace premier control board) Reconnect flow center high voltage power to the correct fused relay circuit of the water furnace premier control board Run test system in cooling mode to test flow center antifreeze fluid level Refill two-three gallons freshwater into QT non-pressurized flow center Suspect ground loop has micro or pinhole leaks. Antifreeze level is down since May Recommend homeowner inspect and refill every 1 to 3 months
Powell, OH 43065
seth p.
seth p. Checked in
Water furnace Envision NDV064 package geothermal system is running in fair condition considering a leaky pressurized ground loop system currently running just above 0 psi that also has one of two float center pumps locked up.. the heavy alcohol antifreeze has a on-site reservoir that is full but not pressurized. Recommend homeowner consider upgrading to new non-pressurized 2 pump flow center. Homeowners original complaint of airflow light flashing and intermittent no cooling throughout the summer was addressed with Waterfurnace tech support for assistance. Tech support explained that airflow lights can be triggered falsely and are a nuisance in water furnace Envision equipment brought forth by older technology. Tech support advised turning dip switch 3-3 to the left to stop sensing for RPM. And explained that if a real problem exists a different service code will appear such as high\low pressure or freezing. Air filter is on schedule quarterly with homeowner but does currently appe
Powell, OH 43065
seth p.
seth p. Checked in
Install an adjust OEM replacement motor shiv and A belt Cooling system tune up maintenance and cleaning Water flush micro channel condenser coil Test fan motor power supply Follow up running refrigerant pressure test after recharge one month ago, pressures are perfectly within balance post cleaning Disassemble clean and flush drain assembly trap All equipment is running in very good condition and ready for the remainder of Summer
Powell, OH 43065
seth p.
seth p. Checked in
was completed on a diff job
Powell, OH 43065
Review
Great service, clean, and courteous. Very friendly. This was an annual check and a piece was broken. They had it on the truck and repaired it that day. Highly recommend.
Pam - Powell, OH 43065
Review
Seth did a great job. He was very knowledgeable and quickly diagnosed our issue.
Patrick - Powell, OH 43065
Review
Great quick service, and did more than I even expected
Alan - Powell, OH 43065
Review
This is my second house that I am using Westin air for servicing, and not just annual HVAC inspections and cleaning. My first house only had one air vent in a large furnished basement. It caused problems. They added more circulation without touching the cosmetics. My 2nd house needs more circulation in the basement due to moisture in the summer. There air no water leaks in the walls to fix. Just stale, moist air forcing me to run the dehumidifier. Their pricing is reasonable for the work and the cost savings from the electric bill is worth it.
Diane - Powell, OH 43065
Review
All went well and to our satisfaction
Gail - Powell, OH 43065
Review
The technicians quickly diagnosed the problem and fix our unit
Charles - Powell, OH 43065
Review
Always helpful
Alan - Powell, OH 43065
Review
Westin still has a 5 star rating with me, though the fact that Westin canceled out original appointment and was late on the rescheduled appointment puts that opinion in jepordy.
Michael - Powell, OH 43065
Review
I'm very satisfied with Weston air. I complement their sales person who came to out home and the office person for her attention. The installation crew was excellent.
chuck - Powell, OH 43065
Review
Thanks for sending Seth.
Rick - Powell, OH 43065
Review
Timely service, good inspection and advise
Charles - Powell, OH 43065
Review
I am very pleased with our service from Westin Air. They are very accommodating to crazy schedules as well.
Kristi - Powell, OH 43065
Review
Awesome
Rick - Powell, OH 43065
Review
Westin Air is one of the most easy to deal with service company I have dealt with in a long time. From the front office staff to the service team everyone is friendly and professional and are very responsive to any question or concern I have had. They stand behind the products they represent and are very easy to deal with. I had a new HVAC system installed about a year ago and have had multiple issues within this time period. Seth my service tech came out and spent numerous hours diagnosing and eventually fixing the problem so I can defiantly say they stand behind the products.
Chris - Powell, OH 43065
Review
Seth arrived within the window and performed annual maintenance on two furnace units. He was courteous while in the home, performed his work timely and made sure to point out items that needed my attention. I have used Westin a number of times over the past year for various properties and have always felt they provided a good service that is reliable and honest. I would recommend Westin to anyone looking for service on their heating/air systems.
Kevin - Powell, OH 43065